Loose Fill Cellulose Insulation R Value

Compare insulation r values before you buy.
Loose fill cellulose insulation r value. R means resistance to heat flow. The higher the r value the greater the insulating power. For loose fill insulation each manufacturer must determine the r value of its product at settled density and create coverage charts showing the minimum settled thickness minimum weight per square foot and coverage area per bag for various total r values. Insulation depth depending on your climate energy codes require varying r values for ceiling insulation.
Achieving the desired r value depends on both the depth of the insulation and its density. R 49 rsi 8 63 15 381 13 5 342 9 12 5 1 163 79 9 86 1 802 8 8 13 1 2 76 8 82 7 r 60 rsi 10 5 18 3 464 3 16 5 417 9 10 0 926 100 3 107 9 2 261 11 04 10 3 1 97 1 104 6 application coverage chart fact sheet greenfiber product ins551ld loose fill cellulose insulation r value 75 f mean temperature minimo de espresor mm. Loose fill cellulose is relatively inexpensive yet still has an r value of about 3 5 per inch of thickness compared to fiberglass r value between r3 to r4 per inch. This is higher than other common loose fill insulation such as fiberglass which averages.
This doesn t represent the whole picture of thermal performance. This calculator is to be used as an estimating tool only. With loose fill cellulose insulation you can achieve an r value of 3 2 to 3 8 per square inch. Loose fill fiberglass by comparison provides an r value of 2 2 to 2 7 per square inch.
Imperial r3 8 per inch which is about the same as or slightly better than glass wool or rock wool. As a loose fill insulation cellulose provides high insulating values represented by its higher r value and it creates a good barrier against air leaks and infiltration. Click the button to calculate the approximate r value for this job. This is r value loose fill cellulose insulation read this before you buy what you should know about r values the chart shows the r value of this insulation.
Loose fill fiberglass has an r value of r 2 2 to 2 7 per inch3. There are other factors to consider. Loose fill fiberglass by comparison provides an r value of 2 2 to 2 7 per square inch. When walls are already finished injecting loose fill cellulose insulation is one of the few ways of adding insulation.
The r value of loose fill cellulose is r 3 2 to 3 8 per inch2. In laboratory testing the average r rating for cellulose insulation is between 3 2 and 3 8 per inch. Metric r2 6 per 100 mm.